You can contact our company for any technical questions you have regarding problems you have in your building. You can send your question to the e-mail: info@dimco.gr or contact directly by phone the Responsible Mechanical Engineer of Technical Support - Mr. Alexandros Machira at (+30) 210-67 24 180, during the company's operating hours us (8:00-16:00) Monday to Friday.

FORGOT YOUR DETAILS?

Gas Automatic Seismic Valves S-Tech

80.00160.00

80.00
80.00
107.00
160.00
160.00
SKU: 2300-0 Categories: ,

Description

Gas Automatic Seismic Valves

S-TECH seismic valves are devices designed to automatically shut off the gas flow in earthquake situations under the conditions defined in the technical standard ASCE25-16, according to PED, ATEX directives and technical standards ANSI Z21. 21-2005, CSA 6.5-2005, CR90 – 002.   It is a completely mechanical device which therefore does not require any electrical power supply.

When the device is subject to seismic vibrations as defined in the technical standards, the SV valve automatically cut-off the gas flow. After the automatic closure, the valve can be reset manually, and it remains closed unti l it is reset allowing the flow of gas.

OPERATION

It is the mechanical earthquake valve that perceives seismic movements [earthquake) and automatically shuts off the flow of gas at the places using gas at the end of perceived movements, then you can manually set it up. It will stay at the turn-off position until you set it up back to the turn-on position. The device automatically turns off at the moment of occurrence of the seismic activity having momentum and frequency values at the size depending on the related standards, as a result of perception of this activity by the device, and in a manner not causing leakage of flow of gas with help of gas shut-off equipment. Whether or not seismic activity continues or not, it remains turn-off until the flow of gas is set up again.

It is possible to give gas to the installation again after device perceived seismic activities and shuts off gas, and the setup knob [reset) is manually pulled . After said shut-off, the manual setup proceeding must be definitely made by authorized gas distribution company or by firms authorized by them.

TECHNICAL FEATURES

Body size Available in 3⁄4” / 1” / 11⁄4” / 11⁄2”/ 2”     Upon request, available in:  1/2″/ 2 – 1/2” / 3” / 4” / 6” / 8” / 10″
Connections Threaded
Work position Horizontal    (upon request models for vertical installation are available)
Working pressure range 0-0,5 bar (0-7 PSI) / 0-4 bar (0-60 PSI)
Design pressure 0,75 bar (10 PSI) / 6 bar (90 PSI)
Acceptable gases Natural gas, town gas, lpg, nitrogen, air, any non-corrosive gas
Operating temperature -23°C ÷ +66 °C (-10°F ÷ +150°F)
Design standards-Approvals PED, ATEX, ASCE25-16, ANSI Z21.21-2005, CR90–002

Technical Brochure: Download 

Installation Manual: Download 

Certification: Download 


Additional information

Weight 3 kg
Manufacturer:

S-Tech Gas Systems